Attach the red wire to the main power input and verify 24V AC at the connection point before proceeding. This ensures the fixture receives consistent voltage without overloading the circuit. Use a multimeter to confirm continuity across the input and ground points.
White and yellow conductors control heating and cooling functions in multi-function units. Connect each wire to its designated slot according to color coding, avoiding cross-connections that can trigger short circuits or system malfunctions. Label each conductor with tape before inserting to maintain clarity during assembly.
Green or blue lines manage fan or auxiliary circuits, allowing independent operation without activating primary components. Tighten each screw and ensure metal surfaces are clean to maintain secure contact under vibration and thermal expansion. Double-check each connection after completing the assembly to guarantee safe operation.
Use the common wire to complete the low-voltage loop. If absent, a power-stealing module or additional transformer may be necessary to maintain functionality. Inspect each connection visually and with a tester before energizing the system to prevent accidental shorts or damage.
3 Conductor Light Holder Connection Guide

Connect the red lead to the power input labeled R and verify 24V AC at the point using a multimeter. Ensure no other conductor shares the same slot to avoid short circuits.
The white cable should attach to the slot controlling heat activation. For dual-stage units, use the secondary slot marked W2 to manage additional heating elements sequentially.
Yellow conductors link to the cooling mechanism. If the system has a second compressor stage, insert the wire into the secondary cooling slot to prevent simultaneous load on both units.
Green or blue lines operate the fan independently. Secure each screw and clean contact points to maintain stable connectivity under vibration and temperature fluctuations.
Confirm all connections visually and with a tester before energizing the circuit. Label each wire clearly during installation to simplify future maintenance and prevent misplacement errors.
Identifying Connections and Corresponding Conductor Colors

Attach the red conductor to the main power input marked R. Verify 24V AC at this point with a multimeter before making any other connections. This is the primary supply line and must remain isolated from other leads.
White wires control heating activation. For systems with multiple stages, use the secondary slot labeled W2 for auxiliary heat. This prevents overloading the main relay and ensures staged operation.

Yellow leads operate the cooling system. If a second-stage compressor is present, connect the wire to Y2 to avoid simultaneous activation of both cooling units. This reduces strain on the system and prevents short cycling.
Green and blue conductors engage fan or auxiliary circuits. They allow airflow without activating heating or cooling elements. Ensure screws are tight and contact surfaces clean to maintain stability under vibration and thermal expansion.
Common wires complete the low-voltage loop. If absent, a power-stealing controller or auxiliary transformer may be required. Always check continuity with a tester before powering the unit to prevent damage.
- Red – 24V AC input
- White – heating stage
- W2 – auxiliary heating
- Yellow – cooling stage
- Y2 – second cooling stage
- Green/Blue – fan operation
- Common – completes circuit
Label each conductor before connecting and double-check color coding against the slots. Visual inspection combined with voltage testing ensures accurate and safe assembly, reducing troubleshooting during operation or seasonal maintenance.